Lab Specification and Setup
Lab and BM RA alignment towards CNTT RA2:
Cloud Infrastructure Software Profile Capabilities
Reference Model Section | Reference | Description | Requirement for Basic Profile | Requirement for Network Intensive Profile | BM RA Notes | OPNFV Intel Lab |
e.cap.001 | Max number of vCPU that can be assigned to a single Pod by the Cloud Infrastructure | At least 16 (1) | At least 16 (1) | [OK] POD 19: 22c/44t [OK] POD 21: 20c/44t | ||
e.cap.002 | Max memory in MB that can be assigned to a single Pod by the Cloud Infrastructure | at least 32 GB(1) | at least 32 GB(1) | [OK] POD 19: 64G [OK] POD 21: 192G | ||
e.cap.003 | Max storage in GB that can be assigned to a single Pod by the Cloud Infrastructure | at least 320 GB(1) | at least 320 GB(1) | [OK] POD 19: 3TB (HDD) [OK] POD 21: 800G (SSD) | ||
e.cap.004 | Max number of connection points that can be assigned to a single Pod by the Cloud Infrastructure | 6 | 6 | Possible through Multus + CNI (vEth, SR-IOV) | ||
e.cap.005 | Max storage in GB that can be attached / mounted to Pod by the Cloud Infrastructure | Up to 16TB(2) | Up to 16TB(2) | |||
e.cap.006 | CPU pinning support | Not required | Must support | Possible through CMK (or Privileged flag) | ||
e.cap.007 | NUMA support | Not required | Must support | (Maybe) Possible through CMK (or other BM RA tool) | ||
e.cap.008 | IPSec Acceleration using the virtio-ipsec interface | Not required | Optional | (??) Might be covered by QAT device plugin |