Lab and BM RA alignment towards CNTT RA2:

Cloud Infrastructure Software Profile Capabilities

Reference Model Section

Reference

Description

Requirement for Basic Profile

Requirement for Network Intensive Profile

BM RA Notes

OPNFV Intel Lab

4.2.5

e.cap.001

Max number of vCPU that can be assigned to a single Pod by the Cloud Infrastructure

At least 16 (1)

At least 16 (1)


[OK] POD 19: 22c/44t

[OK] POD 21: 20c/44t

4.2.5

e.cap.002

Max memory in MB that can be assigned to a single Pod by the Cloud Infrastructure

at least 32 GB(1)

at least 32 GB(1)


[OK] POD 19: 64G

[OK] POD 21: 192G

4.2.5

e.cap.003

Max storage in GB that can be assigned to a single Pod by the Cloud Infrastructure

at least 320 GB(1)

at least 320 GB(1)


[OK] POD 19: 3TB (HDD)

[OK] POD 21: 800G (SSD)

4.2.5

e.cap.004

Max number of connection points that can be assigned to a single Pod by the Cloud Infrastructure

6

6

Possible through Multus + CNI (vEth, SR-IOV)


4.2.5

e.cap.005

Max storage in GB that can be attached / mounted to Pod by the Cloud Infrastructure

Up to 16TB(2)

Up to 16TB(2)



4.2.5

e.cap.006

CPU pinning support

Not required

Must support

Possible through CMK (or Privileged flag)


4.2.5

e.cap.007

NUMA support

Not required

Must support

(Maybe) Possible through CMK (or other BM RA tool)


4.2.5

e.cap.008

IPSec Acceleration using the virtio-ipsec interface

Not required

Optional

(??) Might be covered by QAT device plugin